demo.tracker-v2/code/settings_sys.py

248 lines
6.0 KiB
Python
Raw Normal View History

# Copyright (c) Quectel Wireless Solution, Co., Ltd.All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
import uos
import modem
from machine import UART
from usr.settings_app import default_values_app
2022-04-12 09:13:20 +08:00
PROJECT_NAME = "QuecPython-Tracker"
2022-04-12 09:13:20 +08:00
PROJECT_VERSION = "2.0.1"
2022-04-12 09:13:20 +08:00
DEVICE_FIRMWARE_NAME = uos.uname()[0].split("=")[1]
DEVICE_FIRMWARE_VERSION = modem.getDevFwVersion()
ALERTCODE = {
2022-04-12 09:13:20 +08:00
20000: "fault_alert",
30002: "low_power_alert",
30003: "over_speed_alert",
30004: "sim_abnormal_alert",
30005: "disassemble_alert",
40000: "drive_behavior_alert",
50001: "sos_alert",
}
LOWENERGYMAP = {
"EC200U": [
"POWERDOWN",
"PM",
],
"EC200U": [
"POWERDOWN",
"PM",
],
"EC600N": [
"PM",
],
"EC800G": [
"PM"
],
}
class default_values_sys(object):
2022-04-12 09:13:20 +08:00
"""
System default settings
2022-04-12 09:13:20 +08:00
"""
class _cloud(object):
none = 0x0
quecIot = 0x1
AliYun = 0x2
2022-04-06 19:52:49 +08:00
JTT808 = 0x4
customization = 0x8
class _gps_mode(object):
none = 0x0
internal = 0x1
external = 0x2
class _drive_behavior_code(object):
none = 0x0
quick_start = 0x1
quick_stop = 0x2
quick_turn_left = 0x3
quick_turn_right = 0x4
class _ota_upgrade_status(object):
none = 0x0
to_be_updated = 0x1
updating = 0x2
update_successed = 0x3
update_failed = 0x4
class _ota_upgrade_module(object):
none = 0x0
sys = 0x1
app = 0x2
class _ali_burning_method(object):
one_type_one_density = 0x0
one_machine_one_density = 0x1
2022-04-12 09:13:20 +08:00
"""
variables of system default settings below MUST NOT start with "_"
"""
sw_log = True
checknet_timeout = 60
profile_idx = 1
gps_mode = _gps_mode.external
ota_status = {}
2022-04-06 19:52:49 +08:00
user_ota_action = -1
drive_behavior_code = _drive_behavior_code.none
2022-04-12 09:13:20 +08:00
cloud = _cloud.quecIot
cloud_life_time = 120
cloud_init_params = {}
work_mode_timeline = 3600
ali_burning_method = _ali_burning_method.one_machine_one_density
# trackdev0304 (PROENV)
_quecIot = {
2022-04-12 09:13:20 +08:00
"PK": "p11275",
"PS": "Q0ZQQndaN3pCUFd6",
"DK": "trackdev0304",
"DS": "b56c9cf279b146d7d7a48e7e767362d9",
"SERVER": "iot-south.quectel.com:2883",
}
# # trackerdemo0326 (PROENV)
# _quecIot = {
2022-04-12 09:13:20 +08:00
# "PK": "p11275",
# "PS": "Q0ZQQndaN3pCUFd6",
# "DK": "trackerdemo0326",
# "DS": "32d540996e32f95c58dd98f18d473d52",
# "SERVER": "iot-south.quectel.com:2883",
# }
# # IMEI (PROENV)
# _quecIot = {
2022-04-12 09:13:20 +08:00
# "PK": "p11275",
# "PS": "Q0ZQQndaN3pCUFd6",
# "DK": "",
# "DS": "",
# "SERVER": "iot-south.quectel.com:2883",
# }
# # TrackerDevEC600NCNLC (TESTENV)
# _quecIot = {
2022-04-12 09:13:20 +08:00
# "PK": "p119v2",
# "PS": "TXRPdVVhdkY3bU5s",
# "DK": "TrackerDevEC600NCNLC",
# "DS": "",
# "SERVER": "mqtt://220.180.239.212:8382",
# }
# # IMEI (TESTENV)
# _quecIot = {
2022-04-12 09:13:20 +08:00
# "PK": "p119v2",
# "PS": "TXRPdVVhdkY3bU5s",
# "DK": "",
# "DS": "",
# "SERVER": "mqtt://220.180.239.212:8382",
# }
# tracker_dev_jack
_AliYun = {
2022-04-12 09:13:20 +08:00
"PK": "a1q1kmZPwU2",
"PS": "HQraBqtV8WsfCEuy",
"DK": "tracker_dev_jack",
"DS": "bfdfcca5075715e8309eff8597663c4b",
"SERVER": "a1q1kmZPwU2.iot-as-mqtt.cn-shanghai.aliyuncs.com",
}
_JTT808 = {
2022-04-12 09:13:20 +08:00
"PK": "",
"PS": "",
"DK": "",
"DS": "",
"SERVER": "",
}
locator_init_params = {}
_gps_cfg = {
2022-04-12 09:13:20 +08:00
"UARTn": UART.UART1,
"buadrate": 115200,
"databits": 8,
"parity": 0,
"stopbits": 1,
"flowctl": 0,
}
_cellLocator_cfg = {
2022-04-12 09:13:20 +08:00
"serverAddr": "www.queclocator.com",
"port": 80,
"token": "xGP77d2z0i91s67n",
"timeout": 3,
"profileIdx": profile_idx,
}
_wifiLocator_cfg = {
2022-04-12 09:13:20 +08:00
"token": "xGP77d2z0i91s67n"
}
@staticmethod
def _get_locator_init_params(loc_method):
locator_init_params = {}
if loc_method & default_values_app._loc_method.gps:
2022-04-12 09:13:20 +08:00
locator_init_params["gps_cfg"] = default_values_sys._gps_cfg
if loc_method & default_values_app._loc_method.cell:
2022-04-12 09:13:20 +08:00
locator_init_params["cellLocator_cfg"] = default_values_sys._cellLocator_cfg
if loc_method & default_values_app._loc_method.wifi:
2022-04-12 09:13:20 +08:00
locator_init_params["wifiLocator_cfg"] = default_values_sys._wifiLocator_cfg
return locator_init_params
@staticmethod
def _get_cloud_init_params(cloud):
cloud_init_params = {}
if cloud & default_values_sys._cloud.quecIot:
cloud_init_params = default_values_sys._quecIot
if cloud & default_values_sys._cloud.AliYun:
cloud_init_params = default_values_sys._AliYun
if cloud & default_values_sys._cloud.JTT808:
cloud_init_params = default_values_sys._JTT808
return cloud_init_params
@staticmethod
def _ota_status_init_params():
ota_status = {
2022-04-12 09:13:20 +08:00
"sys_current_version": DEVICE_FIRMWARE_NAME,
"sys_target_version": "--",
"app_current_version": PROJECT_VERSION,
"app_target_version": "--",
"upgrade_module": default_values_sys._ota_upgrade_module.none,
"upgrade_status": default_values_sys._ota_upgrade_status.none,
}
return ota_status